Spectrofluorimetric determination of quercetin in pharmaceutical dosage forms

2014
Authors
Pavun, Leposava
Durdević, Predrag
Jelikic-Stankov, Milena
Đikanović, Daniela

Ciric, Andrija

Uskokovic-Marković, Snežana

Article (Published version)

Metadata
Show full item recordAbstract
A simple, accurate and precise method based on the fluorescence properties of the aluminum(III)-quercetin complex, for the determination of quercetin, has been developed and validated. The complex has strong emission at pH 3.30, lambda(em) = 480 nm, with lambda(ex) = 420 nm. The linearity range of quercetin determination was 1.5-60.5 ng ml(-1) with LOD 0.09 ng ml(-1) and LOQ 0.27 ng ml(-1). Recovery values in the range of 99.9-100.2% indicate a good accuracy of the method. The established method was applied for the determination of quercetin in capsules, with a recovery value of 98.3%, standard deviation of 0.22% and coefficient of variation of 0.09%. The reliability of the method was checked by the newly developed RP-HPLC/UV method for capsules with the direct determination of quercetin after separation. The good agreement between the two methods indicates the applicability of the proposed spectrofluorimetric method for quercetin determination in pharmaceutical dosage forms, with high... reproducibility, and enables the direct and simple determination without its prior extraction from samples. The proposed spectrofluorimetric method has much better sensitivity and LOD and LOQ values that are about 1000 times lower than data reported in the literature.
Keywords:
spectrofluorimetric determination / RP-HPLC / quercetin / flavonoids / capsulesSource:
Macedonian Journal of Chemistry and Chemical Engineering, 2014, 33, 2, 209-215Publisher:
- Soc Chemists Technologists Madeconia, Skopje
Funding / projects:
- Synthesis, modeling, physicochemical and biological properties of organic compounds and related metal complexes (RS-172016)
- Study of structure-function relationships in the plant cell wall and modifications of the wall structure by enzyme engineering (RS-173017)
- Electroconducting and redox-active polymers and oligomers: synthesis, structure, properties and applications (RS-172043)
DOI: 10.20450/mjcce.2014.496
ISSN: 1857-5552
WoS: 000356592500002
Scopus: 2-s2.0-84929326612
Collections
Institution/Community
Institut za multidisciplinarna istraživanjaTY - JOUR AU - Pavun, Leposava AU - Durdević, Predrag AU - Jelikic-Stankov, Milena AU - Đikanović, Daniela AU - Ciric, Andrija AU - Uskokovic-Marković, Snežana PY - 2014 UR - http://rimsi.imsi.bg.ac.rs/handle/123456789/799 AB - A simple, accurate and precise method based on the fluorescence properties of the aluminum(III)-quercetin complex, for the determination of quercetin, has been developed and validated. The complex has strong emission at pH 3.30, lambda(em) = 480 nm, with lambda(ex) = 420 nm. The linearity range of quercetin determination was 1.5-60.5 ng ml(-1) with LOD 0.09 ng ml(-1) and LOQ 0.27 ng ml(-1). Recovery values in the range of 99.9-100.2% indicate a good accuracy of the method. The established method was applied for the determination of quercetin in capsules, with a recovery value of 98.3%, standard deviation of 0.22% and coefficient of variation of 0.09%. The reliability of the method was checked by the newly developed RP-HPLC/UV method for capsules with the direct determination of quercetin after separation. The good agreement between the two methods indicates the applicability of the proposed spectrofluorimetric method for quercetin determination in pharmaceutical dosage forms, with high reproducibility, and enables the direct and simple determination without its prior extraction from samples. The proposed spectrofluorimetric method has much better sensitivity and LOD and LOQ values that are about 1000 times lower than data reported in the literature. PB - Soc Chemists Technologists Madeconia, Skopje T2 - Macedonian Journal of Chemistry and Chemical Engineering T1 - Spectrofluorimetric determination of quercetin in pharmaceutical dosage forms EP - 215 IS - 2 SP - 209 VL - 33 DO - 10.20450/mjcce.2014.496 ER -
@article{ author = "Pavun, Leposava and Durdević, Predrag and Jelikic-Stankov, Milena and Đikanović, Daniela and Ciric, Andrija and Uskokovic-Marković, Snežana", year = "2014", abstract = "A simple, accurate and precise method based on the fluorescence properties of the aluminum(III)-quercetin complex, for the determination of quercetin, has been developed and validated. The complex has strong emission at pH 3.30, lambda(em) = 480 nm, with lambda(ex) = 420 nm. The linearity range of quercetin determination was 1.5-60.5 ng ml(-1) with LOD 0.09 ng ml(-1) and LOQ 0.27 ng ml(-1). Recovery values in the range of 99.9-100.2% indicate a good accuracy of the method. The established method was applied for the determination of quercetin in capsules, with a recovery value of 98.3%, standard deviation of 0.22% and coefficient of variation of 0.09%. The reliability of the method was checked by the newly developed RP-HPLC/UV method for capsules with the direct determination of quercetin after separation. The good agreement between the two methods indicates the applicability of the proposed spectrofluorimetric method for quercetin determination in pharmaceutical dosage forms, with high reproducibility, and enables the direct and simple determination without its prior extraction from samples. The proposed spectrofluorimetric method has much better sensitivity and LOD and LOQ values that are about 1000 times lower than data reported in the literature.", publisher = "Soc Chemists Technologists Madeconia, Skopje", journal = "Macedonian Journal of Chemistry and Chemical Engineering", title = "Spectrofluorimetric determination of quercetin in pharmaceutical dosage forms", pages = "215-209", number = "2", volume = "33", doi = "10.20450/mjcce.2014.496" }
Pavun, L., Durdević, P., Jelikic-Stankov, M., Đikanović, D., Ciric, A.,& Uskokovic-Marković, S.. (2014). Spectrofluorimetric determination of quercetin in pharmaceutical dosage forms. in Macedonian Journal of Chemistry and Chemical Engineering Soc Chemists Technologists Madeconia, Skopje., 33(2), 209-215. https://doi.org/10.20450/mjcce.2014.496
Pavun L, Durdević P, Jelikic-Stankov M, Đikanović D, Ciric A, Uskokovic-Marković S. Spectrofluorimetric determination of quercetin in pharmaceutical dosage forms. in Macedonian Journal of Chemistry and Chemical Engineering. 2014;33(2):209-215. doi:10.20450/mjcce.2014.496 .
Pavun, Leposava, Durdević, Predrag, Jelikic-Stankov, Milena, Đikanović, Daniela, Ciric, Andrija, Uskokovic-Marković, Snežana, "Spectrofluorimetric determination of quercetin in pharmaceutical dosage forms" in Macedonian Journal of Chemistry and Chemical Engineering, 33, no. 2 (2014):209-215, https://doi.org/10.20450/mjcce.2014.496 . .