RIMSI - Репозиторијум Института за мултидисциплинарна истраживања
Универзитет у Београду - Института за мултидисциплинарна истраживања
    • English
    • Српски
    • Српски (Serbia)
  • Српски (ћирилица) 
    • Енглески
    • Српски (ћирилица)
    • Српски (латиница)
  • Пријава
Преглед записа 
  •   RIMSI
  • Institut za multidisciplinarna istraživanja
  • Radovi istraživača / Researchers’ publications
  • Преглед записа
  •   RIMSI
  • Institut za multidisciplinarna istraživanja
  • Radovi istraživača / Researchers’ publications
  • Преглед записа
JavaScript is disabled for your browser. Some features of this site may not work without it.

Spectrofluorimetric and HPLC Determination of Morin in Human Serum

Thumbnail
2009
346.pdf (78.27Kb)
Аутори
Pavun, Leposava
Đikanović, Daniela
Durdević, P.
Stankov, M.J.
Malešev, D.
Ćirić, A.
Чланак у часопису (Објављена верзија)
Метаподаци
Приказ свих података о документу
Апстракт
Morin is a flavonol antioxidant. In ethanol-water mixtures (70 wt% of ethanol) it reacts with Al3+ to give Al(Morin)(2) in the pH range 3-6. The conditional stability constant of this complex at 298 K was found to be log beta(2) = 16.96 +/- 0.02 at pH 4.40. The complex shows strong fluorescence emission at 500 nm upon excitation at 410 nm. The fluorescence intensity is pH dependent with maximum emission at pH 4.40. Since the complexation reaction enhances the fluorescence of morin, this property was used for the determination of morin in human serum. A linear dependence of the intensity of fluorescence of the complex on the concentration of morin was obtained in morin concentration range from 1.5-30.5 ng mL(-1), relative standard error of measurements was 1.4%. The LOD was 0.02 ng mL(-1) while LOQ was 1.0 ng mL(-1). Serum concentration of morin was also determined using HPLC as a reference method. A C-18 Hypersil Gold AQ column was used with acetonitrile-0.1% v/v phosphoric acid (30:70...% v/v) as the mobile phase at 1.0 mL min(-1) flow rate and UV detection at 250 nm. Acceptable relative standard errors (less than 5%) between determinations obtained by the two methods indicate that the fluorescence method is reliable.

Кључне речи:
spectrofluorimetry / serum / Morin / determination / aluminium
Извор:
Acta Chimica Slovenica, 2009, 56, 4, 967-972
Издавач:
  • Slovenian Chemical Society
Финансирање / пројекти:
  • Биоактивни комплекси p и d јона метала са лигандима фармакотерапијског значаја (RS-142013)
  • Испитивања нових биосензора за мониторинг и дијагностику биљака (RS-143043)

ISSN: 1318-0207

WoS: 000273279400026

Scopus: 2-s2.0-74849114036
[ Google Scholar ]
20
17
Handle
https://hdl.handle.net/21.15107/rcub_rimsi_349
URI
http://rimsi.imsi.bg.ac.rs/handle/123456789/349
Колекције
  • Radovi istraživača / Researchers’ publications
Институција/група
Institut za multidisciplinarna istraživanja
TY  - JOUR
AU  - Pavun, Leposava
AU  - Đikanović, Daniela
AU  - Durdević, P.
AU  - Stankov, M.J.
AU  - Malešev, D.
AU  - Ćirić, A.
PY  - 2009
UR  - http://rimsi.imsi.bg.ac.rs/handle/123456789/349
AB  - Morin is a flavonol antioxidant. In ethanol-water mixtures (70 wt% of ethanol) it reacts with Al3+ to give Al(Morin)(2) in the pH range 3-6. The conditional stability constant of this complex at 298 K was found to be log beta(2) = 16.96 +/- 0.02 at pH 4.40. The complex shows strong fluorescence emission at 500 nm upon excitation at 410 nm. The fluorescence intensity is pH dependent with maximum emission at pH 4.40. Since the complexation reaction enhances the fluorescence of morin, this property was used for the determination of morin in human serum. A linear dependence of the intensity of fluorescence of the complex on the concentration of morin was obtained in morin concentration range from 1.5-30.5 ng mL(-1), relative standard error of measurements was 1.4%. The LOD was 0.02 ng mL(-1) while LOQ was 1.0 ng mL(-1). Serum concentration of morin was also determined using HPLC as a reference method. A C-18 Hypersil Gold AQ column was used with acetonitrile-0.1% v/v phosphoric acid (30:70% v/v) as the mobile phase at 1.0 mL min(-1) flow rate and UV detection at 250 nm. Acceptable relative standard errors (less than 5%) between determinations obtained by the two methods indicate that the fluorescence method is reliable.
PB  - Slovenian Chemical Society
T2  - Acta Chimica Slovenica
T1  - Spectrofluorimetric and HPLC Determination of Morin in Human Serum
EP  - 972
IS  - 4
SP  - 967
VL  - 56
UR  - https://hdl.handle.net/21.15107/rcub_rimsi_349
ER  - 
@article{
author = "Pavun, Leposava and Đikanović, Daniela and Durdević, P. and Stankov, M.J. and Malešev, D. and Ćirić, A.",
year = "2009",
abstract = "Morin is a flavonol antioxidant. In ethanol-water mixtures (70 wt% of ethanol) it reacts with Al3+ to give Al(Morin)(2) in the pH range 3-6. The conditional stability constant of this complex at 298 K was found to be log beta(2) = 16.96 +/- 0.02 at pH 4.40. The complex shows strong fluorescence emission at 500 nm upon excitation at 410 nm. The fluorescence intensity is pH dependent with maximum emission at pH 4.40. Since the complexation reaction enhances the fluorescence of morin, this property was used for the determination of morin in human serum. A linear dependence of the intensity of fluorescence of the complex on the concentration of morin was obtained in morin concentration range from 1.5-30.5 ng mL(-1), relative standard error of measurements was 1.4%. The LOD was 0.02 ng mL(-1) while LOQ was 1.0 ng mL(-1). Serum concentration of morin was also determined using HPLC as a reference method. A C-18 Hypersil Gold AQ column was used with acetonitrile-0.1% v/v phosphoric acid (30:70% v/v) as the mobile phase at 1.0 mL min(-1) flow rate and UV detection at 250 nm. Acceptable relative standard errors (less than 5%) between determinations obtained by the two methods indicate that the fluorescence method is reliable.",
publisher = "Slovenian Chemical Society",
journal = "Acta Chimica Slovenica",
title = "Spectrofluorimetric and HPLC Determination of Morin in Human Serum",
pages = "972-967",
number = "4",
volume = "56",
url = "https://hdl.handle.net/21.15107/rcub_rimsi_349"
}
Pavun, L., Đikanović, D., Durdević, P., Stankov, M.J., Malešev, D.,& Ćirić, A.. (2009). Spectrofluorimetric and HPLC Determination of Morin in Human Serum. in Acta Chimica Slovenica
Slovenian Chemical Society., 56(4), 967-972.
https://hdl.handle.net/21.15107/rcub_rimsi_349
Pavun L, Đikanović D, Durdević P, Stankov M, Malešev D, Ćirić A. Spectrofluorimetric and HPLC Determination of Morin in Human Serum. in Acta Chimica Slovenica. 2009;56(4):967-972.
https://hdl.handle.net/21.15107/rcub_rimsi_349 .
Pavun, Leposava, Đikanović, Daniela, Durdević, P., Stankov, M.J., Malešev, D., Ćirić, A., "Spectrofluorimetric and HPLC Determination of Morin in Human Serum" in Acta Chimica Slovenica, 56, no. 4 (2009):967-972,
https://hdl.handle.net/21.15107/rcub_rimsi_349 .

DSpace software copyright © 2002-2015  DuraSpace
О репозиторијуму RIMSI | Пошаљите запажања

OpenAIRERCUB
 

 

Комплетан репозиторијумГрупеАуториНасловиТемеОва институцијаАуториНасловиТеме

Статистика

Преглед статистика

DSpace software copyright © 2002-2015  DuraSpace
О репозиторијуму RIMSI | Пошаљите запажања

OpenAIRERCUB