Spectrofluorimetric and HPLC Determination of Morin in Human Serum
Abstract
Morin is a flavonol antioxidant. In ethanol-water mixtures (70 wt% of ethanol) it reacts with Al3+ to give Al(Morin)(2) in the pH range 3-6. The conditional stability constant of this complex at 298 K was found to be log beta(2) = 16.96 +/- 0.02 at pH 4.40. The complex shows strong fluorescence emission at 500 nm upon excitation at 410 nm. The fluorescence intensity is pH dependent with maximum emission at pH 4.40. Since the complexation reaction enhances the fluorescence of morin, this property was used for the determination of morin in human serum. A linear dependence of the intensity of fluorescence of the complex on the concentration of morin was obtained in morin concentration range from 1.5-30.5 ng mL(-1), relative standard error of measurements was 1.4%. The LOD was 0.02 ng mL(-1) while LOQ was 1.0 ng mL(-1). Serum concentration of morin was also determined using HPLC as a reference method. A C-18 Hypersil Gold AQ column was used with acetonitrile-0.1% v/v phosphoric acid (30:70...% v/v) as the mobile phase at 1.0 mL min(-1) flow rate and UV detection at 250 nm. Acceptable relative standard errors (less than 5%) between determinations obtained by the two methods indicate that the fluorescence method is reliable.
Keywords:
spectrofluorimetry / serum / Morin / determination / aluminiumSource:
Acta Chimica Slovenica, 2009, 56, 4, 967-972Publisher:
- Slovenian Chemical Society
Funding / projects:
- Bioaktivni kompleksi p i d jona metala sa ligandima farmakoterapijskog značaja (RS-142013)
- Ispitivanja novih biosenzora za monitoring i dijagnostiku biljaka (RS-143043)
Collections
Institution/Community
Institut za multidisciplinarna istraživanjaTY - JOUR AU - Pavun, Leposava AU - Đikanović, Daniela AU - Durdević, P. AU - Stankov, M.J. AU - Malešev, D. AU - Ćirić, A. PY - 2009 UR - http://rimsi.imsi.bg.ac.rs/handle/123456789/349 AB - Morin is a flavonol antioxidant. In ethanol-water mixtures (70 wt% of ethanol) it reacts with Al3+ to give Al(Morin)(2) in the pH range 3-6. The conditional stability constant of this complex at 298 K was found to be log beta(2) = 16.96 +/- 0.02 at pH 4.40. The complex shows strong fluorescence emission at 500 nm upon excitation at 410 nm. The fluorescence intensity is pH dependent with maximum emission at pH 4.40. Since the complexation reaction enhances the fluorescence of morin, this property was used for the determination of morin in human serum. A linear dependence of the intensity of fluorescence of the complex on the concentration of morin was obtained in morin concentration range from 1.5-30.5 ng mL(-1), relative standard error of measurements was 1.4%. The LOD was 0.02 ng mL(-1) while LOQ was 1.0 ng mL(-1). Serum concentration of morin was also determined using HPLC as a reference method. A C-18 Hypersil Gold AQ column was used with acetonitrile-0.1% v/v phosphoric acid (30:70% v/v) as the mobile phase at 1.0 mL min(-1) flow rate and UV detection at 250 nm. Acceptable relative standard errors (less than 5%) between determinations obtained by the two methods indicate that the fluorescence method is reliable. PB - Slovenian Chemical Society T2 - Acta Chimica Slovenica T1 - Spectrofluorimetric and HPLC Determination of Morin in Human Serum EP - 972 IS - 4 SP - 967 VL - 56 UR - https://hdl.handle.net/21.15107/rcub_rimsi_349 ER -
@article{ author = "Pavun, Leposava and Đikanović, Daniela and Durdević, P. and Stankov, M.J. and Malešev, D. and Ćirić, A.", year = "2009", abstract = "Morin is a flavonol antioxidant. In ethanol-water mixtures (70 wt% of ethanol) it reacts with Al3+ to give Al(Morin)(2) in the pH range 3-6. The conditional stability constant of this complex at 298 K was found to be log beta(2) = 16.96 +/- 0.02 at pH 4.40. The complex shows strong fluorescence emission at 500 nm upon excitation at 410 nm. The fluorescence intensity is pH dependent with maximum emission at pH 4.40. Since the complexation reaction enhances the fluorescence of morin, this property was used for the determination of morin in human serum. A linear dependence of the intensity of fluorescence of the complex on the concentration of morin was obtained in morin concentration range from 1.5-30.5 ng mL(-1), relative standard error of measurements was 1.4%. The LOD was 0.02 ng mL(-1) while LOQ was 1.0 ng mL(-1). Serum concentration of morin was also determined using HPLC as a reference method. A C-18 Hypersil Gold AQ column was used with acetonitrile-0.1% v/v phosphoric acid (30:70% v/v) as the mobile phase at 1.0 mL min(-1) flow rate and UV detection at 250 nm. Acceptable relative standard errors (less than 5%) between determinations obtained by the two methods indicate that the fluorescence method is reliable.", publisher = "Slovenian Chemical Society", journal = "Acta Chimica Slovenica", title = "Spectrofluorimetric and HPLC Determination of Morin in Human Serum", pages = "972-967", number = "4", volume = "56", url = "https://hdl.handle.net/21.15107/rcub_rimsi_349" }
Pavun, L., Đikanović, D., Durdević, P., Stankov, M.J., Malešev, D.,& Ćirić, A.. (2009). Spectrofluorimetric and HPLC Determination of Morin in Human Serum. in Acta Chimica Slovenica Slovenian Chemical Society., 56(4), 967-972. https://hdl.handle.net/21.15107/rcub_rimsi_349
Pavun L, Đikanović D, Durdević P, Stankov M, Malešev D, Ćirić A. Spectrofluorimetric and HPLC Determination of Morin in Human Serum. in Acta Chimica Slovenica. 2009;56(4):967-972. https://hdl.handle.net/21.15107/rcub_rimsi_349 .
Pavun, Leposava, Đikanović, Daniela, Durdević, P., Stankov, M.J., Malešev, D., Ćirić, A., "Spectrofluorimetric and HPLC Determination of Morin in Human Serum" in Acta Chimica Slovenica, 56, no. 4 (2009):967-972, https://hdl.handle.net/21.15107/rcub_rimsi_349 .